Electrophysiology Equipment
High-voltage energy transfer + precise ablation control
Circon delivers high-voltage connector solutions benchmarked to top international brands—covering Pulsed Field Ablation (PFA), Radio-Frequency (RF) and Cryo ablation—helping EP device makers tackle high-voltage transfer, insulation and system stability.

Overview
As Pulsed Field Ablation (PFA) rapidly enters atrial fibrillation therapy via irreversible electroporation, kV-level pulses and μs-level discharge place extreme demands on connectors. We provide high-voltage solutions compliant with IEC 60664-4, dual-certified to ISO 13485 / ISO 9001, using insert molding and precision potting for long-term reliability.
Gallery

Market Drivers
- PFA rapidly replaces traditional ablation—non-thermal, safer, faster
- Precise control of kV-level (2000–5000VDC) and μs-level discharge
- Insulation and arcing control per IEC 60664-4
- Coexistence of PFA / RF / Cryo demands full-coverage connectivity
Technical Advantages
kV-level High-Voltage Transfer
| Voltage range | 1000V–5000VDC HV pulse |
| Insulation | Creepage/clearance per IEC 60664-4 |
| Hipot test | 5000VAC / 6000VDC |
| Material CTI | CTI > 600 |
μs-level Pulse Precision
| Transient suppression | Low parasitic inductance design |
| Impedance matching | Custom 50Ω / 75Ω |
| Long-term reliability | High-hipot medical-grade material |
Material & Process
| Insert molding | Integrated structure, precise terminals |
| Precision potting | Improves insulation stability |
Industry Challenges
- Stable kV-level HV transfer and insulation control
- μs-level transient suppression and impedance matching
- Insert molding + potting for long-term reliability
Typical Applications
- PFA / RF / Cryo ablation devices
- Cardiac EP mapping systems
- Ablation catheters and hand-held devices
Application Scenarios
PFA Pulsed Field Ablation
- Host: B-series HV connector, 4–8 contacts
- Catheter: plastic 2P series, 4–6 contacts
- Mapping electrode: T-series micro connector
RF Ablation
- Host output: B-series high-current (5A–10A)
- Catheter: plastic 2P or K-series (power+temp+impedance)
- Foot switch: K-series IP68 waterproof
Cryo Ablation / EP Mapping
- Cryo: B-series special connector (low-temp, sealed)
- Mapping catheter: T-series low-noise micro connector
- Host interface: B-series high-density multi-channel
成功案例 / Success Cases
A PFA Ablation Device Maker
挑战 / Challenge:The catheter-to-host connector had to carry 4000V pulses with μs-level discharge while meeting IEC 60664-4 creepage requirements; traditional connectors suffered frequent arc breakdown.
方案 / Solution:Deployed a custom B-series HV connector (CTI > 600 insulation + precision potting), with optimized contact spacing and insulation barriers.
成果 / Result:Passed 5000VAC hipot, zero breakdown across 500 pulse cycles, enabling the customer's IEC 60601-1 type test clearance.
An EP Mapping System OEM
挑战 / Challenge:The mapping catheter micro-connector needed 8-channel low-noise transmission inside an φ8mm envelope, plus ETO sterilization compatibility.
方案 / Solution:Selected T-series micro connector with optimized spring design for < 5mΩ contact resistance, using ETO-compatible medical-grade materials.
成果 / Result:Signal noise < 10μV, zero performance degradation after 200 ETO cycles, now in volume supply.
Certifications
ISO 13485 Medical QMSISO 9001 QMSIEC 60664-4 HV insulationRoHS / REACH medical-grade material
Have an interconnect challenge? Our engineers are ready to help.
From standard products to custom solutions, Circon powers your next project.