R2
Shell Sizes & Variants
Select a shell size to explore available models.
0B·Shell Size — 1 available variants
Dimensions & Drawings
Technical Specifications
Series-level typical values; refer to drawings and test reports for specific models.
| Parameter | Metal B Series Applicable: 00 / 0B / 1B / 2B / 3B / 4B | Metal 00 Coaxial Series Applicable: 00 | Metal 01 Coaxial Series Applicable: 01 |
|---|---|---|---|
| Mechanical | |||
| Shell material | Aluminum | Copper alloy | Copper alloy |
| Locking | Push-pull self-locking | Push-pull self-locking | Push-pull self-locking |
| Mating cycles | ≥ 10,000 cyclesIEC 60512-5-1 | — | — |
| Environmental | |||
| IP rating (mated) | IP50IEC 60529 | IP50 (reference)IEC 60529 | IP50 (reference)IEC 60529 |
| Electrical | |||
| Contacts | 2–27 contacts | 1 coaxial (C5 50 Ω) | 1 coaxial (C5 50 Ω) |
| Rated current | Up to 35 A per contactVaries by contact count, wire gauge and model | — | — |
| Dielectric withstand | Up to 3.5 kVContact-to-contact test voltageIEC 60512-4-1 | — | — |
| Impedance | — | 50 Ω | 50 Ω |
Need technical assistance?
Contact our team for product selection, drawings and sample inquiries.
Contact Our Team